BASE-LOK® FASTENERS
Product Information

Uses:
  • Base sheet fastener
Fastener Testing Results
Printable Image of Data Sheet (PDF Format)
Fastening Patterns: (PDF Format)
-- Tectum Deck
-- Gypsum Deck
-- Lightweight Concrete Deck

Sizes & Quantities:


#
Shank
Length
Shank
Gage
Fastening Range
Max. Total Thickness
Required
Deck
Penetration
*Pieces /
Pound
Box
*Pieces /
Box
Pounds /
Box
1
1 3/4"
0.39"
0.0625"
1.5"
40
1000
25
  *Approximate Count

Design Options:
Shank
Types
Coating
Types
Container
Types
Cap
Diameters
Nail Materials
Spiral
Capron*
Boxes
3"
Heat-Stabilized,
Glass Fiber-Reinforced Nylon Compound
*Allied Signal’s Capron (a heat-stabilized glass fiber-reinforced nylon compound)

Design Features:

Approvals:

Deck Type
FMRC
Approval
Lap
Spacing
Field Spacing
Row 1
Field Spacing
Row 2
Lightweight Concrete
I-90
9"
12"
12"
Cementitious Wood Fiber
I-90
9"
18"
18"
*Refer to the factory manual research Corporation Building Materials Approval Guide before specifying or installing Base-Lok

Pullout Results:

Average Pullout Resistance (lbs.)
Base-Lok®
Light Weight Concrete
186
Gypsum
195
Cementitious Wood Fiber
191.5
Tested by Exterior Research & Design, LLC, Inc.
Test performed in compliance with Dade County Protocol PA 105 (A) and 117 (A).
Gypsum test performed by Simplex Nails and Fasteners

Recommended Tools:

DeWalt DW995 Cordless Adjustable Clutch Driver/Drill
DeWalt DW269 Heavy Duty Versa Clutch Driver/Drill (0 - 1,000 RPM’s)