SIMPLEX RUPTURE DISCS
Product
Testing Results
| Test Report: |
100-97 |
| Product: |
2" Rupture Plate |
| Test: |
Rupture Value |
| Procedure: |
Dade County Protocol PA 117(B) |
|
Manufacturer
|
Base Sheet Type
|
Rupture in (lbf)
|
|
Celotex
|
Hydrostop
|
183.5
|
|
GAF
|
GAFGLAS #75
|
105.3
|
|
GAF
|
GAFGLAS Stratavent
|
115.9
|
|
GS Roofing
|
All Weather / Empire
|
109.8
|
|
GS Roofing
|
GS Flex Base 30
|
113.4
|
|
GS Roofing
|
GS Flex-I-Glas Base
|
120.8
|
|
GS Roofing
|
GS Glassbase
|
151.6
|
|
GS Roofing
|
PolySMS Base
|
406.0
|
|
Malarkey
|
#603 Superbase
|
110.4
|
|
Malarkey
|
#501 Premium I Modified Base
|
113.4
|
|
Malarkey
|
#515 Fiberglass Standard Base
|
146.4
|
|
Malarkey
|
#605 Panoply
|
198.3
|
|
Johns Manville
|
Glasbase
|
106.9
|
|
Johns Manville
|
Ventsulation
|
112.2
|
|
Johns Manville
|
Dynabase
|
114.1
|
|
SOPREMA
|
Modified Sopra-G
|
100.6
|
|
SOPREMA
|
Sopra-G
|
124.6
|
|
SOPREMA
|
Sopravent
|
130.7
|
|
SOPREMA
|
Sopraglass 100
|
171.9
|
|
SOPREMA
|
Sopralene 180
|
284.9
|
|
U.S. Intec
|
Intec Bondable Base
|
76.5
|
|
U.S. Intec
|
Intec Ultrabase
|
105.8
|
|
U.S. Intec
|
Intec P190
|
380.5
|
|
U.S. Intec
|
Permavent
|
109.8
|
Apply suitable factor of safety to arrive at design
loads. The above results were obtained under laboratory conditions.
| Test Report: |
100-97 |
| Product: |
3" Rupture Plate |
| Test: |
Rupture Value |
| Procedure: |
Dade County Protocol PA 117(B) |
|
Manufacturer
|
Base Sheet Type
|
Rupture in (lbf)
|
|
Celotex
|
Hydrostop
|
|
|
GAF
|
GAFGLAS #75
|
|
|
GAF
|
GAFGLAS Stratavent
|
|
|
GS Roofing
|
All Weather / Empire
|
|
|
GS Roofing
|
GS Flex Base 30
|
|
|
GS Roofing
|
GS Flex-I-Glas Base
|
|
|
GS Roofing
|
GS Glassbase
|
|
|
GS Roofing
|
PolySMS Base
|
|
|
Malarkey
|
#603 Superbase
|
|
|
Malarkey
|
#501 Premium I Modified Base
|
|
|
Malarkey
|
#515 Fiberglass Standard Base
|
|
|
Malarkey
|
#605 Panoply
|
|
|
Johns Manville
|
Glasbase
|
|
|
Johns Manville
|
Ventsulation
|
|
|
Johns Manville
|
Dynabase
|
|
|
SOPREMA
|
Modified Sopra-G
|
|
|
SOPREMA
|
Sopra-G
|
|
|
SOPREMA
|
Sopravent
|
|
|
SOPREMA
|
Sopraglass 100
|
|
|
SOPREMA
|
Sopralene 180
|
|
|
U.S. Intec
|
Intec Bondable Base
|
|
|
U.S. Intec
|
Intec Ultrabase
|
|
|
U.S. Intec
|
Intec P190
|
|
|
U.S. Intec
|
Permavent
|
|
Apply suitable factor of safety to arrive at design