Manufacturer Of The "Original" Cap Nail.    Phone: (800) 328-0857

Discs Uses:
  • Increases Rupture Resistance To Softer Materials (Base Sheets and Insulation)
2" Fastener Testing Results
3" Fastener Testing Results

Product Testing Results

Test Report: 100-97
Product: 2" Rupture Plate
Test: Rupture Value
Procedure: Dade County Protocol PA 117(B)

Manufacturer
Base Sheet Type
Rupture in (lbf)
Celotex
Hydrostop
183.5
GAF
GAFGLAS #75
105.3
GAF
GAFGLAS Stratavent
115.9
GS Roofing
All Weather / Empire
109.8
GS Roofing
GS Flex Base 30
113.4
GS Roofing
GS Flex-I-Glas Base
120.8
GS Roofing
GS Glassbase
151.6
GS Roofing
PolySMS Base
406.0
Malarkey
#603 Superbase
110.4
Malarkey
#501 Premium I Modified Base
113.4
Malarkey
#515 Fiberglass Standard Base
146.4
Malarkey
#605 Panoply
198.3
Johns Manville
Glasbase
106.9
Johns Manville
Ventsulation
112.2
Johns Manville
Dynabase
114.1
SOPREMA
Modified Sopra-G
100.6
SOPREMA
Sopra-G
124.6
SOPREMA
Sopravent
130.7
SOPREMA
Sopraglass 100
171.9
SOPREMA
Sopralene 180
284.9
U.S. Intec
Intec Bondable Base
76.5
U.S. Intec
Intec Ultrabase
105.8
U.S. Intec
Intec P190
380.5
U.S. Intec
Permavent
109.8

Apply suitable factor of safety to arrive at design loads. The above results were obtained under laboratory conditions.


3" Test Results

Test Report: 100-97
Product: 3" Rupture Plate
Test: Rupture Value
Procedure: Dade County Protocol PA 117(B)

Manufacturer
Base Sheet Type
Rupture in (lbf)
Celotex
Hydrostop
GAF
GAFGLAS #75
GAF
GAFGLAS Stratavent
GS Roofing
All Weather / Empire
GS Roofing
GS Flex Base 30
GS Roofing
GS Flex-I-Glas Base
GS Roofing
GS Glassbase
GS Roofing
PolySMS Base
Malarkey
#603 Superbase
Malarkey
#501 Premium I Modified Base
Malarkey
#515 Fiberglass Standard Base
Malarkey
#605 Panoply
Johns Manville
Glasbase
Johns Manville
Ventsulation
Johns Manville
Dynabase
SOPREMA
Modified Sopra-G
SOPREMA
Sopra-G
SOPREMA
Sopravent
SOPREMA
Sopraglass 100
SOPREMA
Sopralene 180
U.S. Intec
Intec Bondable Base
U.S. Intec
Intec Ultrabase
U.S. Intec
Intec P190
U.S. Intec
Permavent

Apply suitable factor of safety to arrive at design loads. The above results were obtained under laboratory conditions.